  • Construction power cable PVC insulated & sheathed with copper / aluminum conductor

    Model: 1.Model No:227 IEC 01 BV-PVC insulated copper conductor power cable BLV- PVC insulated aluminum c...
    Use:

    Construction power cable PVC insulated & sheathed with copper / aluminum conductor,suitable for AC rated voltage not over UO/U450/750V power, lighting, electric appliances, testing or comminication equipments.-澳门新葡京8455.com

    Standard: GB/T5023-2008,JB8734-2012
    Characteristic:

    1、Uo/U : 450/750 or 300/500。

    2、Allowance of long term working temperature for cable:BV-90 not over 90℃,rest models of this type of cable not over 70℃。

    3、Temperature should be above 1℃ while laying.。

    4、Bending Radius Allowed: a minimum 4D is required for cables outer diameter less that 25mm, cables outer diameter over 25mm,minimum requirement is 6D.。

    Details>>
  • YJV22、YJLV22 XLPE insulated, steel tape armored PVC sheathed power cable with copper / aluminum conductor

    Model: XLPE insulated, steel tape armored PVC sheathed power cable with copper / aluminum conductor
    Use:

    The XLPE  insulation  power  cable  has  high  mechanical  strength,good electrical specification,and chemical resistance, use for AC voltage U0/U 0.6/1kV power distribution, can be laid indoor, overhead or tunnels.

    Standard: GB/T12706.1-2008
    Characteristic:

    Operating characteristic:

    a, Temperature should be above 0℃ and bending radius should not be less than 10 times of the outer diameter of the cable while lying.

    b,Regular long time working temperature of conductor should be below 90℃。

    c,If short circuit occurs (lasting time less than 5s), the maximum

    temperature of the cable will not exceed 250℃.

    Details>>
  • YJV、YJLV XLPE insulated, PVC sheathed power cable with copper / aluminum conductor

    Model: XLPE insulated, PVC sheathed power cable with copper / aluminum conductor
    Use:

    The XLPE  insulation  power  cable  has  high  mechanical  strength,good electrical specification,and chemical resistance, use for AC voltage U0/U 0.6/1kV power distribution, can be laid indoor, overhead or tunnels.

    Standard: GB/T12706.1-2008
    Characteristic:

    Operating characteristic:

    a, Temperature should be above 0℃ and bending radius should not be less than 10 times of the outer diameter of the cable while lying.

    b,Regular long time working temperature of conductor should be below 90℃。

    c,If short circuit occurs (lasting time less than 5s), the maximum

    temperature of the cable will not exceed 250℃.

    Details>>
  • VV22,VLV22-PVC insulated, steel wire armored PVC / PE sheathed power cable with copper / aluminum conductor

    Model: VV22,VLV22-PVC insulated, steel wire armored PVC / PE sheathed power cable with copper / aluminum conductor
    Use:

    The products can be ly laid in places where cable can be protected from certain mechanical force, such as indoor, underground, cable conduit or tunnel for power transmission and distribution line project, with rated A/C Uo/u being 0.6/1KV or below.

    Standard: GB/T12706-2008
    Characteristic:

    Operating Characteristics:

    a. Temperature should be above 0℃ and bending radius should not be less than 10 times of the outer diameter of the cable while lying.

    b. Regular long time working temperature of conductor should be below 70℃

    c. If short circuit occurs (lasting time less than 5s), the maximum temperature of the cable will not exceed 160℃.

    Details>>
  • VLV-PVC insulated, PVC sheathed power cable with copper / aluminum conductor

    Model: VV,VLV-PVC insulated, PVC sheathed power cable with copper / aluminum conductor
    Use:

    The products can be ly laid in various environments such as indoor,aerial,cable conduit or tunnel for  power  transmission and distribution line project,with rated A/C UO/U no more than 0.6/1KV-新葡京娱乐客户端下载

    Standard: GB/T 12706-2008
    Characteristic:

    Operating Characteristics:

    a. Temperature should be above 0℃ while laying.

    b. Regular long time working temperature of conductor should be below 70℃

    c. If short circuit occurs (lasting time less than 5s), the maximum temperature of the cable will not exceed 160℃.

    Details>>